According to the national roofing contractors association nrca a power vent with an airflow rate of 1 0 cubic foot per minute per square foot of attic space measured at the attic floor is generally considered to be equivalent to a 1 150 ventilation ratio.
Irc 2012 attic ventilation requirements.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Based on your 1100 sq.
However unvented attics can reduce residential energy needs and are allowed by the code under certain conditions.
And this guideline you ll need a minimum of.
Unvented attic assemblies code notes 2009 irc 2012 irc adequate attic ventilation is a long standing requirement in building codes for moisture control.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
Near ridge of the roof.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Always have a balanced ventilation system.
Space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
One ventilation opening shall be within 3 feet 915 mm of each corner of the building.
The minimum net area of ventilation openings shall not be less than 1 square foot 0 0929 m2 for each 150 square feet 14 m2 of under floor area.
Overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches 51 mm above the low point of the roof or overflow scuppers having three times the size of the roof drains and having a minimum opening height of 4 inches 102 mm shall be installed in the adjacent parapet walls with the inlet flow located 2 inches 51 mm above the low point of the roof served.
Vented attics shall have a minimum net free ventilation area at least 1 300 of the area of the vented space.
Between half and two thirds of the provided ventilation shall be installed at the eaves.